| MFG Code 38381-0 | Part Number BC4003 |
| 320 watts | 132 volts |
| E39 (Mogul Screw) Base Type | ED-28 Bulb Type |
| Clear Finish | 62 CRI |
| 21000 Lumens | 20000 hrs. |
| 4100 K | 3.5" Bulb Diameter |
| 5" Light Center Len | 8.3125" Max Overall Len |
Manufacturer: |
|
|
BulbConnection is an Authorized Distributor for Philips products. As an Authorized Distributor, this item is guaranteed to be an authentic, brand new, genuine Philips part supplied directly from Philips. |
|
|
|
|
|
|
|
|
![]() |
![]() |
|
||||||
|
||||||
Product Description |
||
Pulse Start Metal Halide, High Intensity Discharge Lamps. Nickel plated brass base. Heat resisting glass bulb. Equivalent to Venture MS320W/H75/ED28/PS. 12NC Logistics code: 928601152501. Philips Pulse Start Metal Halide Lamps offer an optimized metal halide system for greater efficiency and lumen maintenance. |
||
Description:
The Philips MS320/U/PS replacement bulb has a Philips product code of 38381-0.
This Philips MS320/U/PS bulb is a 320 watt bulb. The Philips Pulse Start MH Std 320W/640 Mog lamp is a 132 volt bulb.
The Philips Pulse Start MH Std 320W/640 Mog replacement lamp has a part number of BC4003.
The bulb type of this Philips PS MH Std 320W/640 Mog ED28 CL bulb is type ED-28. The base type of the Philips Pulse Start MH Std 320W/640 Mog replacement lamp may also be called ED28. The Philips Pulse Start MH Std 320W/640 Mog replacement bulb has a base type of E39 (Mogul Screw). The maximum overall length of the Philips PS MH Std 320W/640 Mog ED28 CL replacement lamp is 8.313 inches or 211.1 millimeters. The bulb diameter of the Philips Pulse Start MH Std 320W/640 Mog replacement lamp is 3.500 inches or 88.9 millimeters. The light center length of this Philips Pulse Start MH Std 320W/640 Mog bulb is 5.000 inches or 127.0 millimeters. The Philips PS MH Std 320W/640 Mog ED28 CL replacement lamp is often referred to by the product code 38381-0.
The Philips MS320/U/PS replacement bulb has a reorder code of BC4003.
Other order codes that the Philips MS320/U/PS replacement bulb may be referred to as are MS320/U/PS, MS320UPS, MS320 U PS, MS320-U-PS, Pulse Start MH Std 320W/640 Mog, PulseStartMHStd320W/640Mog, Pulse Start MH Std 320W640 Mog, Pulse/Start/MH/Std/320W/640/Mog, Pulse-Start-MH-Std-320W/640-Mog, Pulse Start MH Std 320W 640 Mog, Pulse Start MH Std 320W-640 Mog, PS MH Std 320W/640 Mog ED28 CL, PSMHStd320W/640MogED28CL, PS MH Std 320W640 Mog ED28 CL, PS/MH/Std/320W/640/Mog/ED28/CL, PS-MH-Std-320W/640-Mog-ED28-CL, PS MH Std 320W 640 Mog ED28 CL, PS MH Std 320W-640 Mog ED28 CL. The manufacturer continuous use average life rating for this Philips Pulse Start MH Std 320W/640 Mog lamp is 20000 hours. The color temperature of this replacement bulb is 4100 degrees Kelvin. The rated lumens value of the Philips MS320/U/PS replacement lamp is 21000. The color rendering index of the Philips PS MH Std 320W/640 Mog ED28 CL replacement lamp is 62. The Philips Pulse Start MH Std 320W/640 Mog replacement bulb has a Clear finish. The operating position of this replacement lamp is Universal.
|
||
Specifications |
||
| General Specifications | |||
Watts |
320WATTS A unit of electrical power. Lamps are rated in watts to indicate the rate at which they consume energy. This Philips 38381-0 Bulb is rated at 320 watts. |
||
Volts |
132VOLTS A measure of "electrical pressure" between two points. The higher the voltage, the more current will be pushed through a resistor connected across the points. The volt specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 277 V) refers to the line voltage it must be connected to. This Philips 38381-0 Bulb is rated at 132 volts. |
||
Base Type |
E39 (Mogul Screw)BASE TYPE The base is the end of the lamp that fits into the receptacle connected to the electrical supply. There are many types of bases used in lamps, screw bases being the most common for incandescent and HID lamps, while bipin bases are common for linear fluorescent lamps. This Philips 38381-0 Bulb has a base type of E39 (Mogul Screw). |
||
Bulb Type |
ED-28BULB TYPE The bulb type refers to the shape and class of the bulb. This Philips 38381-0 Bulb has a base type of ED-28. |
||
Rated Average Life |
20000 hrsRATED AVERAGE LIFE This is the manufacturer provided rating for the average expected life of a lamp. For most lamp types, rated lamp life is the length of time of a statistically large sample between first use and the point when 50% of the lamps have failed. Note, this is not a manufacturer guarantee of life, but an estimate based on typical average testing. It is possible to define a "useful life" of a lamp based on practical considerations involving lumen depreciation and color shift. This Philips 38381-0 Bulb has an rated average life of 20000 hours. |
||
Color Temperature |
4100 KCOLOR TEMPERATURE A measure indicating the degree of "yellowness" or "blueness" of a white light source. Measured in kelvins, Color Temperature represents the temperature an incandescent object (like a filament) must reach to mimic the color of the light emitting from the lamp. Yellowish-white ("warm") sources, like incandescent lamps, have lower color temperatures in the 2700K-3000K range; white and bluish-white ("cool") sources, such as cool white (4100K) and natural daylight (6000K), have higher color temperatures. The higher the color temperature the whiter, or bluer, the light will be. The lower the color temperature the more yellow the light will be. This Philips 38381-0 Bulb has a color temperature of 4100 K. |
||
Lumens |
21000LUMENS A measure of the luminous flux or quantity of light emitted by a source. For example, a dinner candle provides about 12 lumens. A 60-watt Soft White incandescent lamp provides about 840 lumens. This Philips 38381-0 Bulb emits 21000 lumens. |
||
Color Rendering Index (CRI) |
62COLOR RENDERING INDEX (CRI) An international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more true colors generally appear. CRI ratings of various lamps may be compared, but a numerical comparison is only valid if the lamps are close in color temperature. CRI differences among lamps are not usually significant (visible to the eye) unless the difference is more than 3-5 points. This Philips 38381-0 Bulb is rated at 62 CRI color rendering index. |
||
Operating Position |
UniversalOPERATING POSITION Mercury and High Pressure Sodium lamps may be operated in any burn position and will still maintain their rated performance specifications. Metal Halide and Low Pressure Sodium lamps, however, are optimized for performance in specific burn positions, or may be restricted to certain burn positions for safety reasons. This Philips 38381-0 Bulb has an operating position of Universal. |
||
Bulb Finish |
ClearBULB FINISH The bulb coating of the bulb. Typical values include clear, frost, and colored. This Philips 38381-0 Bulb has a Clear bulb finish. |
||
| Dimensions | |||
Maximum Overall Length (MOL) |
8.313 in (211.1 mm) |
||
Bulb Diameter |
3.500 in (88.9 mm) |
||
Light Center Length (LCL) |
5.000 in (127.0 mm) |
||
| Product Specifications | |||
Manufacturer Product Code |
38381-0 (383810) |
||
Part Number |
BC4003 |
||
Ordering Code(s) |
MS320/U/PS Pulse Start MH Std 320W/640 Mog PS MH Std 320W/640 Mog ED28 CL |
||
Standard Case Size (listed prices are per lamp) |
12 |
||
UPC |
046677383817 |
||
Usage Notes |
||
Pulse start metal halide is designed for operation on only specified ANSI compatible ballasts with metal halide pulse ignitor. Use ANSI code ballast ref: M154/M132/E. |
||
Safety Notices & Warnings |
||
| Safety Notices & Warnings: | ||
These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." This lamp complies with FDA radiation performance standard 21 CFR subchapter J. |
||